Bracing an Unreinforced Brick Stack

Is This About Your House?

By sending, you agree Bedford Chimney Care may contact you by call, automated text or email about your request. Consent isn't required to buy. Msg & data rates may apply; reply STOP to opt out. Privacy Policy

Brick chimney tops against a clear blue sky

Ask the owner of a 1924 bungalow what worries them about the house and the chimney comes up early. It is tall, it is brick, and it went up before anyone put steel in house masonry. Bedford Chimney Care prices seismic work on chimneys across Fullerton, La Habra and Orange, and the same three choices come up on nearly every visit. This page sets them out so you know what you are being offered and what to ask about it.

Why this is an older-house problem

A chimney built today has upright steel bars grouted into it and metal ties into the floor and roof framing. A chimney from the 1910s through the 1930s has neither. It is stacked brick held by lime mortar, standing beside a timber house and joined to it by little more than the roof flashing. When the ground shakes, the tall part above the roof has nothing to steady it, and the mortar bed at the roofline turns into a hinge.

That is the damage older chimneys are known for after Southern California quakes, the 1987 Whittier Narrows quake among them: tops cracked through at the roof, turned on their base or brought down, while the houses under them stood. The lower chimney, boxed in by the house, usually comes off better.

So the retrofit question is nearly always about the part above the roof and the connection to the house. The three answers differ in how much of the original chimney they keep.

Choice one: bracing above the roof

Where a chimney stands high above the roofline, steel braces can be fixed from a collar around the upper stack to blocking set into the roof frame. The brace shortens the height left unsupported. It is the least disruptive of the three, leaves every brick where it is, and suits a stack whose masonry is in good order. It can be seen from the street, which matters to some owners of period houses and not to others. A brace does nothing for brick that is already loose. Steel fixed to a weak stack only gives the weak stack a handle.

Choice two: strapping at the ceiling and roof lines

Steel straps can be passed around the chimney where it meets the ceiling and roof framing and bolted back into the joists or rafters, so that house and chimney are tied at each level. Much of this work happens in the attic and cannot be seen once it is done. It suits a chimney that climbs the outside wall of the house, where a gap can open between brick and siding. Whether it can be done at all depends on what the attic framing offers to bolt to and whether there is room to work, which is why this choice cannot be priced from the yard.

Choice three: rebuilding from the roofline up

The third route removes the brick above the roof and replaces it. The new top can be reinforced masonry built to resemble the old, or a light metal flue inside a framed and finished enclosure, which lifts most of the weight off the roof altogether. That second kind limits what the fireplace may burn to what the new flue is rated for, so it pairs naturally with a gas insert. On houses where the view from the street matters, a careful mason can reuse the original face brick over a reinforced core.

This is the only one of the three that deals with a top already cracked, leaning or loose. It is also the most work.

How we arrive at a recommendation

A recommendation comes out of four checks, all part of our $390 Level 2 inspection.

The stack is sighted against a level for lean and twist. The joints at and above the roofline are probed, because that hinge point tells most of the story. The attic is entered to see what holds the chimney now, whether earlier straps exist and are still fixed to anything, and what timber is on hand for new anchors. Then the camera goes through the flue, since a chimney that moved in a past quake often shows it as a band of broken tile at one height before anything shows outside.

The written report states the condition of each and says which of the three choices the chimney qualifies for. Sound brick with a tall exposed top: bracing or strapping. Sound lower chimney with a damaged top: a roofline rebuild. Damage running below the roof: a larger rebuild, described on our chimney rebuilds page.

If your chimney predates the 1940s and has never been checked for ties, or you can see a crack line near the roof, use the contact page to tell us the age of the house and where the chimney stands and ask for a retrofit assessment. The inspection is arranged first and the choices are priced from its report.

What the quote spells out

A retrofit quote from us names the choice, the steel or framing to be used in ordinary words, where it attaches, and what will be visible afterwards from the street and from inside the attic. Where a rebuild is involved, the line where old brick ends and new work begins is drawn on a picture of your own chimney. Any masonry repair needed before steel can go on, such as repointing the upper courses, is a line of its own with its own figure. If the city wants drawings or sign-off for the chosen route, the quote says who handles that.

We print no price for seismic work. The spread between a brace on a short single-story stack and a roofline rebuild on a two-story Spanish house is too wide for a range to mean anything.

What a retrofit does not claim

No honest contractor will tell you a braced or strapped pre-war chimney is now the equal of a new reinforced one, and we will not either. The aim of bracing and strapping is narrower: keep the top from coming off and keep the stack against the house. Rebuilding with steel goes further. None of the three turns a fireplace with a cracked flue into a usable one, which is a separate finding with a repair of its own. We also make no statement about rebate programs or insurance terms. Those belong to the agencies and insurers that run them.

Questions for any bidder

Did you go into the attic? What exactly does the steel attach to? Is the brick above the roof sound enough to take it, and how did you test that? What will I see from the sidewalk afterwards? If you take the top down, what goes back, and can I still burn wood? A bidder who answers with pictures has done the looking.

Where to go from here

Our chimney seismic retrofit page covers the service in more depth. To have a pre-war chimney in Fullerton assessed and the choices priced, get in touch through the contact page.

Wondering Where Your Own Chimney Stands?

Bedford Chimney Care works from Fullerton on the fireplaces of older houses. We find out what the flue, firebox and stack are actually made of, then put the findings and a price for each repair in writing.

Call (657) 233-4679