Charming houses with vibrant facades under a clear blue sky in Sapanca, Türkiye.

Chimney and Fireplace Care for the Older Homes of Fullerton

Ask for a Visit

Leave your number and a line about the house. We phone back to agree a day.

Flue filmedPrices in writingCallback by phone
Written Quote Before Work
Photos With Every Report
Mortar Matched to Old Brick
Original Tile Protected
NFPA 211 Inspection Levels
Working From Fullerton
Written Quote Before Work
Photos With Every Report
Mortar Matched to Old Brick
Original Tile Protected
NFPA 211 Inspection Levels
Working From Fullerton
Our Services

What we do for a Fullerton fireplace, from inspection to rebuild.

Which service fits depends on how the chimney was built and how it has aged. An inspection answers both.

01

Chimney Sweep

Soot and glazed creosote taken off old clay tile gently, so worn joints and missing mortar show up before the next fire.

Brush head chosen for the age and shape of the tile
Smoke shelf emptied by hand, not vacuumed past
Throat damper freed and worked once the soot is off
Drop cloths from the door to the hearth, sealed vacuum running
Read more
02

Chimney Inspection

A Level 1 visit that reads the hearth, throat, reachable flue and rooftop brickwork, then puts each finding on paper in plain terms.

Firebox floor, walls and lintel read for loose or burnt brick
Cast-iron damper opened, closed and judged on how it seats
Flue viewed from the hearth and from the roof with a strong light
Top courses, mortar wash and cap looked over at roof level
Read more
03

Chimney Repair

Repairs matched to how the stack was first built, from loose top courses to a failed flue, each priced on paper before work begins.

Top courses relaid where the bond has let go
Broken mortar wash cut away and recast
Cracked flue tile dealt with by section or by relining
Earlier patches opened up where they hide damage
Read more
04

Fireplace Inspection

A room-side inspection of an original fireplace: firebrick, throat, lintel, hearth and the tile or brick face around the opening.

Firebrick sounded for hollow or loose units
Lintel sighted for sag and rust
Throat and smoke chamber viewed from below with a light
Hearth extension depth and support confirmed
Read more
05

Fireplace Repair

Burnt-out firebrick, open back-wall joints, sagging lintels and tired dampers put right without stripping an original fireplace of its character.

Failed firebrick cut out and relaid in refractory mortar
Back-wall and floor joints repacked
Sagged or rusted lintel reset or replaced
Smoke chamber coated smooth with a heat-rated mix
Read more
06

Chimney Level 2 Inspection

For a flue nobody has seen inside in decades: a recorded camera pass, hidden framing checked, and a report a buyer can act on.

Recorded camera pass over every liner tile and joint
Hidden passes through the house checked for timber against brick
All Level 1 items covered during the same visit
Unlined or part-lined sections identified and measured
Read more
07

Chimney Cap Installation

Many old flues were left open to the sky; we measure the tile and fasten a screened lid that suits the stack.

Flue tile measured on the roof before ordering
Top of the stack tested for a sound fixing
Screen mesh fine enough to stop embers and nesting birds
Full-width covers made for stacks with two or more flues
Read more
08

Chimney Flashing Repair

New step and counter metal where an old stack meets the roof, fitted after we find out exactly how rain is getting past.

Layers of old tar and patch metal stripped back
Water path found before any new metal is cut
Step pieces lapped under the roofing course by course
Counter pieces let into raked mortar joints
Read more
09

Chimney Masonry Repair

Repointing and brick replacement for old stacks, using mortar the original brick can live with and units chosen to match its color.

Existing mortar tested before a mix is chosen
Joints cut back by hand near fragile brick faces
New pointing tooled to the original joint profile
Failed brick replaced with salvaged or color-matched units
Read more
10

Chimney Rebuilds

When an old stack is past pointing, we dismantle it as far as the damage runs and build it back to the original pattern.

Dismantled only as far as the failure runs
Sound original brick cleaned and reused
Bond pattern and corbelling copied from the old stack
New flue tile, cast top and flashing included
Read more
11

Fireplace Cleaning

Room-side cleaning of the firebox, grate, doors and surround, done with products that will not etch period tile or soft brick.

Ash lifted and firebrick brushed down
Cleaners spot-tested before touching period tile
Door glass, frames and tracks cleaned
Smoke staining taken off the face and mantel shelf
Read more
12

Gas Fireplace Cleaning

Yearly service for gas fires and log sets fitted into older fireboxes: dust out, ports clear, glass bright, flame observed.

Logs lifted out, dusted and placed per the manual
Lint and soot flakes blown out of the burner ports and pilot
White film removed from the glass with a ceramic-safe cleaner
Door seal and latches looked over
Read more
13

Gas Fireplace Repair

Fault-finding on gas fires and log sets, including the older valves and key-operated burners still found in period fireplaces.

Supply pressure and isolation valve tested first
Pilot flame and its sensor measured with a meter
Valve, wall switch and remote wiring tested in turn
Old key valves and pipe burners assessed for continued use
Read more
14

Fireplace Remodel

Updates to a period fireplace that keep what is worth keeping: a new hearth, repaired tile, a rebuilt face or a sympathetic mantel.

Original tile and mantel assessed for repair before removal
Firebox and flue inspected ahead of any finish work
Hearth depth and trim distances set from the opening
Paint and later cladding stripped where the old face survives
Read more
15

Fireplace Inserts

Gas, wood or electric heaters fitted inside an old firebox with their own liner, so the original flue is no longer doing the work.

Box measured for width, depth, height and arch
Flue filmed before a unit is recommended
Dedicated stainless liner from the unit to the flue top
Trim panel cut to the opening so the old face stays
Read more
16

Pellet Stove Repair

Diagnosis and parts for a pellet stove that has quit, plus a look at its exhaust route through an old wall or flue.

Display code read and the fault reproduced
Fuel-metering motor, igniter and blowers tested one at a time
Safety switches and vacuum hose examined
Ash passages and exhaust pipe cleared
Read more
17

Wood Stove Repair

Door seals, baffles, firebrick and flue connections renewed on freestanding stoves and on stoves set into an old hearth.

Door rope and glass seal tested and replaced
Baffle and brick lining inspected for warp and cracks
Air controls freed and adjusted
Stovepipe joints and the chimney entry examined
Read more
18

Gas Logs

Ceramic log sets and burners chosen to fit a period firebox, connected to the existing gas stub or a new line, then test-fired.

Box measured so burner and logs suit the opening
Existing gas stub and floor key tested before reuse
Flue confirmed clear and drawing first
Damper fixed open on sets that exhaust up the chimney
Read more
19

Chimney Seismic Retrofit

Bracing, anchoring or a lighter upper section for plain brick chimneys built before steel in masonry was routine.

Inspection first to confirm the brick is worth anchoring
Steel anchors from the stack into roof and ceiling structure
Brace above the roofline for tall freestanding tops
Option to swap upper brickwork for a light framed section
Read more
20

Chimney Crown Repair

The mortar wash on top of an old stack resurfaced, or replaced with a cast top that sheds rain past the brick below.

Top photographed close up so you can judge its condition
Crazed but firmly attached tops resurfaced with a brush-on membrane
Broken tops removed down to the last sound course
New top cast thicker, with an edge that projects past the brick
Read more
21

Dryer Vent Cleaning

Lint cleared from the full duct run, including the long or improvised routes common where a laundry was added to an old house.

Whole duct cleaned from the machine end and the outlet end
Outside hood, flap and screen cleared
Airflow measured before and after the cleaning
Sagging foil hose and crushed sections flagged
Read more
22

Chimney Liner Installation

A continuous stainless or cast lining for flues built unlined, or whose clay tile has cracked, shifted or washed out at the joints.

Flue filmed and measured before a lining is specified
Liner diameter worked out from the appliance it serves
Continuous stainless run with no joints inside the flue
Insulation added where old brick sits close to timber
Read more
23

Chimney Leak Repair

Water tracing on an old stack, from open flue top to roof joint to porous brick, followed by the repair that stops that entry.

Hose test worked upward from the roof joint
Attic watched while the water runs
Cap, top surface and brick faces each ruled in or out
Entry point photographed and named in the quote
Read more
24

Chimney Waterproofing

A clear breathing treatment for soft old brick that has started to darken, flake or grow moss after wet winters.

Brick tested for how fast it takes up water
Open joints and failed tops repaired beforehand
Surface cleaned of moss and salts, then left to dry
Soak-in treatment that leaves the wall able to dry out
Read more
25

Chimney Damper Repair

Seized, rusted or missing cast-iron throat dampers freed, rebuilt or replaced with a cable-operated lid at the flue top.

Blade, hinge and handle freed and tested
Seat examined for gaps that leak house air
Broken handles and linkages replaced where parts exist
Cable-operated lid at the flue top when the casting is finished
Read more
26

Chimney Chase Cover

A new stainless lid for the stucco or wood chimney surround on a mid-century or later house, replacing a rusted galvanized one.

Dimensions taken on the roof, flue position included
Lid folded in stainless with a pitched top
Edges turned down past the top of the stucco or siding
Joint around the flue pipe sealed against driven rain
Read more
Lit corner fireplace with a white mantel in a living room

Flue, Firebox, Stack

Three parts of an old chimney, each judged on its own terms.

Based in Fullerton

A chimney company for houses with some history.

Bedford Chimney Care is based in Fullerton and works mainly on houses with some age to them: pre-war bungalows, Spanish Revival homes and the ranch houses of the 1950s and 1960s. Their fireplaces were built by hand, to the habits of their day.

Those habits matter now. Flues were often left unlined, mortar was soft and rich in lime, and dampers were cast iron set into the throat. None of that is a defect in itself, but each one changes how a repair ought to be done.

So a first visit is about finding out. We film the flue, go over the firebox and hearth by hand, and study the stack from the roof. After that you receive photographs, plain findings and a written price for anything worth doing.

Flue filmed before any advice is given

Mortar matched to the brick already there

Original tile and mantels kept in place

Findings sorted into sound, watch and repair

In Short

We keep what still works, repair what can be repaired and tell you plainly about the rest.

History comes up only when it changes the job or the price.

The House Comes First

Original brick, tile and ironwork stay wherever they can still do their job safely. We repair before we replace, and say so when replacement is the honest answer.

Materials That Suit the Age

Lime-rich mortar for soft brick, refractory in the firebox, stainless for new liners. The wrong material on old masonry does more harm than no repair at all.

History Only Where It Counts

We explain how your chimney was built when that changes the work or the price. Otherwise we skip the lecture and get on with the job.

Everything in Writing

Findings, photographs and prices arrive on paper before work begins. Each repair is its own line, so nothing rides along unasked.

Common Questions

What Fullerton owners ask about older fireplaces

Unlined flues, old mortar, inspection levels and prices, answered as we would at your hearth. Something missing? Ring (657) 233-4679.

Often it is, but nobody can say so from the living room. Fireplaces of that age went up before clay liners were routine, with thin firebrick and timber nearer the masonry than anyone would place it today. We look at four things: whether the flue has a liner and what state it is in, whether the firebox brick is still tight, what the hearth rests on, and how near the framing sits. Many pass with modest repairs. Some are safer converted to a lined gas insert, and the report tells you which yours is.
An unlined brick flue was normal building practice a century ago, so this is a common finding in Fullerton bungalows. There are three routes. A stainless liner suits a gas insert, a stove or gas logs. A cast lining keeps an open wood fireplace in use. Or the fireplace can be retired from burning and kept as a feature. A Level 2 camera inspection gives us the size and condition of the flue, and the written quote compares the routes that fit.
Start from what you know about the flue. If the fireplace has been in steady use, was looked at recently and nothing about it is changing, a Level 1 at $165 deals with everything reachable without tools or a camera. If you are buying or selling, fitting an insert or logs, or simply have no record of anyone ever filming the flue, book a Level 2 at $390, which brings the recorded camera pass and the concealed areas. Level 3 is reserved for the unusual case where part of the structure must be opened to follow a known problem.
Because mortar is meant to be the weaker partner. Early brick is soft and was laid in a lime-rich mix that flexes and lets damp escape through the joints. A modern high-cement mortar is stiffer and denser than that brick, so stress and trapped water go into the brick faces, which then flake off. We test what is in the wall and repoint with a mix the old brick can live beside. It is the difference between a repair that helps and one that harms.
Yes, and we plan the job around them. Period tile, a clinker brick face or an old-growth mantel is usually worth more to the house than the repair itself. We mask the face, work from inside the box, and cut out firebrick by hand next to anything fragile. If a tile is already loose or cracked we tell you before starting and agree whether to reset it, leave it or source a match.
These are our set figures. Level 1 inspection: $165. Level 2 inspection with recorded video: $390. Sweeping: from $415. Tracing and repairing a leak: $555 to $3,350. A roof cricket: $445 to $1,005, or $670 to $1,650 with new flashing all round. A gas insert fitted to the hearth you have: $2,750 to $5,550. A new direct-vent gas fire somewhere other than the old hearth: $4,450 to $8,950. A fitted cap is quoted after we measure. Masonry, liners, crowns, dampers and rebuilds vary too much from house to house for a list price, so each gets a written figure once we have inspected.
While your inspection contingency is still open. A house inspector deals with the fireplace in a line or two and normally refers the flue to a chimney specialist, and with an older house that referral is where the real cost can sit: an unlined flue, a hearth on timber, a stack that needs rebuilding above the roof. A Level 2 puts those on video and in writing, so you can ask for a repair, ask for a credit or simply know what you are taking on. The report goes to you and to anyone you name.
Yes. Wood smoke in Orange County is regulated by the South Coast Air Quality Management District. When the district posts a mandatory no-burn notice, which happens in the colder months, its Rule 445 makes lighting a wood fire a violation, period fireplace or not. The district publishes the daily status, so look before you light. Gas log sets and gas inserts fall outside those bans, one reason owners of older houses convert. Our Ventura County customers come under a separate air district with its own rules.
That depends on the casting. A blade that is only rusted to its seat can usually be freed, cleaned and re-hung. A cracked frame or a snapped pivot is different: replacement throat dampers rarely fit an old firebox without cutting brick, so we fit a lid at the flue top instead, worked by a stainless cable that hangs inside the firebox. It closes more tightly than the original ever did. Where both routes are possible you get both prices in writing.
Plain brick stacks were standard on houses of that age, and this region has a record of them breaking at the roofline, the 1987 Whittier Narrows quake being the local example. Whether yours needs work depends on its height above the roof, the state of the mortar and how it meets the framing. After an inspection we set out the realistic choices, from anchoring and bracing to replacing the upper section with something lighter, with a written price for each. No retrofit can promise how a stack will behave, and we say that plainly too.
Yes. Fullerton is home, and La Habra, Orange and Cerritos are the cities we are in most weeks. The areas page lists every other city on our routes, with a page for each. Put the address in the contact form and we will confirm coverage when we call.
Use the form on the contact page. Give the address, the age of the house if you know it and what prompted you to get in touch. We call back, settle which inspection fits, and agree a visit. Afterwards you receive photographs, written findings and a separate price for each repair. Nothing is started until you have approved it in writing.
Original Fireplace, Unknown Flue

Find out what your Fullerton chimney is made of and what it can safely do

We film the flue, go over the firebox and hearth, and study the stack from the roof. Then the findings and a price for each repair reach you in writing. Ring the number or fill in the form.

(657) 233-4679

The form reaches the office directly

Tell Us About the House

A line is plenty: the decade it was built, what the fireplace burns, why you are asking.

By sending, you agree Bedford Chimney Care may contact you by call, automated text or email about your request. Consent isn't required to buy. Msg & data rates may apply; reply STOP to opt out. Privacy Policy

Where We Work

North Orange County first, then the cities around it

140 cities have a page here, and each says what the age of its houses means for a chimney. Look yours up.

What We Meet in These Houses

Age, alterations and weather, in different measure from city to city

A bungalow from the 1920s, a ranch house from the 1950s and a tract home from the 1970s each have a different chimney behind the wall. The city pages say which you are likely to own.

Flues with no liner

Common in the oldest houses. A camera settles the question, and the report sets out what can be done about it.

Mortar gone soft

Lime mortar weathers out of the top courses first. We repoint with a mix the old brick tolerates, not the hardest one on the shelf.

Fireplaces altered over the years

Gas lines, inserts and patched fireboxes left by earlier owners explain many surprises, so we look for them on every visit.

How a Job Runs

From first form to finished repair

Finding out comes before fixing. Nothing is priced until we have seen it, and nothing is touched until you approve the price.

01

Send the Basics

Fill in the form on the contact page with the street address, the era of the house if you know it, and your reason for asking. A person reads every request.

02

We Call to Set the Visit

We phone back with a few questions about the fireplace and settle which inspection fits: Level 1 for a hearth in regular use, Level 2 for a sale, a new appliance or a flue with no history.

03

The House Gets Read

On the day we cover the floors, then go over the firebox, the flue, the attic pass and the rooftop, photographing as we go. In an old house we also look for past alterations, because those explain most surprises.

04

Report and Written Prices

You receive the photographs, the findings in plain language, and a separate written price for each repair, so the pressing ones can go first and the rest can wait.

05

Work, Then a Walk-Round

Approved work is scheduled and original materials are protected while it happens. At the end we show you the finished job and tell you how long new mortar needs before a fire.

Call (657) 233-4679

Or use the contact page. Someone at the office reads each request and phones back.

Call (657) 233-4679