Twelve months, every fireplace, one calendar

Plan a portfolio round

The plan, quarter by quarter

The calendar is drawn up with you, one building at a time, and the months below are the pattern we propose for a portfolio in and around Fullerton. It follows the weather and the burning season, so that looking happens on dry roofs and fixing is finished before residents want a fire.

A portfolio of two buildings fits the same pattern as one of twenty. The difference is only how many visits each quarter holds.

  • January to March: approved repairs carried over from the previous round, and any unit that changed hands over the winter.
  • April to June: buildings from before 1960, where masonry fireplaces and shared stacks take the longest to examine.
  • July to September: later buildings with factory-made fireplaces and metal flues, and sweeping for the units whose records called for it.
  • October to December: record sheets delivered and filed, with return visits only for units that could not be entered earlier.

Why the oldest buildings lead

Courtyard apartments, duplexes and converted houses from the 1920s to the 1950s have brick fireplaces whose history nobody on the current staff witnessed. One stack may carry three or four flues from different units. Caps may be missing, tops may have been patched by a roofer, and a gas log lighter may have been added to a firebox built for wood. These buildings take the most time per hearth and benefit most from being seen in spring, when a finding still has two dry seasons in which to be repaired.

The yearly inspection looks at the hearth and firebox, works the damper, sights up the flue as far as its shape allows, and examines the top, the cap and the roof joint from above. When a unit reports smoke in the room, when a fire has burned inside a flue, after a quake, or when a building is going up for sale, that unit is moved to the camera inspection at $390.

A record sheet for each hearth

Every fireplace gets its own dated sheet: building, unit, fuel, what was found, pictures, and a first line saying whether the fireplace may be used. The layout stays identical from year to year, so an owner or a board can lay two years side by side and see what changed.

Sheets go to the manager who ordered the round and to the owner or board contact named when the calendar was agreed. What an insurer or lender accepts as a record is theirs to say. The sheet gives them a date, the findings and the pictures.

Entry and residents

Notices to residents are the manager's to send under the lease or the association's rules. We supply a unit-by-unit schedule for each visit to attach to them. Inside a unit we need a few clear feet in front of the hearth and either an adult resident or a staff member with a key.

Units that could not be entered are listed on the building's summary and picked up when we return for the next building on the calendar, so one locked door does not hold up a whole round.

Charged by the fireplace

The yearly round is charged per hearth, so a building can be totalled from its unit list.

Yearly inspection, charged for each fireplace (Level 1)
$165
Camera inspection where a unit's findings call for one (Level 2)
$390
Sweeping a flue the round found sooted
from $415

Repairs are listed unit by unit once the round is done, each with its own figure, for the owner or board to approve.

Questions from managers and boards

How is a building with forty fireplaces charged?

Forty yearly inspections at $165 apiece. The total is checked against your unit list before the round goes on the calendar. Camera inspections at $390 and sweeping from $415 are added only for the units whose records call for them.

Our buildings date from different decades. Does that change anything?

It sets the order. Masonry fireplaces from before 1960 are seen first and take longer per unit. Later factory-made units with metal flues follow. The yearly fee per fireplace does not change with the age of the building.

Who receives the record sheets?

The manager who ordered the round, plus the owner or board contact named when the calendar was agreed.

What happens when a fireplace should not be used?

Its sheet says so in the first line, with the reason and a picture, and the manager hears it from us before we leave the building. Telling the resident, and any steps under the lease, are the manager's.

Do gas-only fireplaces belong in the yearly round?

Yes. A gas unit still vents through a flue or a wall terminal that can block or corrode, and an old gas log set in a brick fireplace relies on the damper staying open. The inspection covers the vent path and the burner parts that can be seen. Gas appliance repair is priced apart.

Can an association order the shared parts only?

Yes. A board can order the round for the stacks, tops and caps the association maintains. Owners can add the inside of their own units to the same visit for the same per-fireplace fee.

Put next year's round on paper

List your buildings and their fireplace counts on the contact form. We phone back with a calendar proposal and the total for the yearly inspections.

Call (657) 233-4679