What the camera saw, and what puts it right
Have a failed flue priced
List the findings your report names and say whether the fireplace burns wood or gas. We phone back about a visit to measure and price the repair.
Three flue findings and the answer to each
A flue has one job, which is to carry heat and gas out of the house without letting either reach the chimney wall. Each of the findings below is a way of failing at that job. On chimneys from before the 1950s they often appear together, since the tiles, the joints and the brick behind them are all the same age.
What the report calls a failure is a statement about use: the fireplace is not to be lit as it stands. It is not a statement that the chimney must come down. Most failed flues in older houses are answered from the inside, with the brickwork left alone.
- Split tile: a stainless liner run inside the flue. Where the split is confined to the top tile or two, those tiles can sometimes be replaced from the roof.
- Open or washed-out joints between sound tiles: the joints can be resurfaced from inside. Where tiles have also slipped out of line, a liner.
- No tile at all, only brick: an insulated stainless liner sized to the fireplace or to the appliance it will serve.
Choosing a liner for an older flue
The liner's width is set by what it serves. An open wood fireplace needs a wide one, in proportion to the opening, and a narrow pre-war flue cannot always take that width once insulation is added. We measure the inside of the flue, its height and every bend before proposing anything. If the liner an open fire needs will not pass, the choices are to break out the old tile for room or to change what the fireplace burns.
That second choice is why so many failed flues end with an insert. A gas insert vents through slim pipes of its own that pass almost any flue, and it turns a fireplace that lost heat into one that gives it. We fit a gas insert, vent pipes included, for $2,750 to $5,550. A wood insert with its own liner is measured and priced per house.
What else a failed report tends to list
Flue findings rarely arrive alone. The same report on an older chimney usually notes a flue open to the sky, which a fitted cap answers, quoted after we measure, and the price depends on how many flues it spans and whether it has to be made to measure. It may note water getting in at the roof joint, which our leak work covers at $555 to $3,350, and a wide stack with nothing upslope to split the flow, which a saddle answers at $445 to $1,005, or $670 to $1,650 with the flashing renewed.
Other common lines have no printed price and are measured: a broken mortar top, a damper frame rusted solid, timber sitting too close to the brick in the attic, a firebox wall that has moved. By up to standard we mean the repair follows NFPA 211 and the maker's instructions for any liner or appliance fitted. Whether your city wants a permit depends on the work, and the quote says if one applies and who files it.
After the work
When the repair is finished you receive pictures of each completed line and a note stating which findings from the report are now closed. A new camera recording of a relined flue can be included when you want proof of the finished interior for a sale file or for your own records. The papers go to whoever ordered the work and to anyone they name.
Printed prices for the usual fixes
Where a repair repeats closely from one house to the next, we publish its range. Liners for open fireplaces, masonry tops, dampers and chase covers are measured and priced per house.
- Gas insert with its own vent pipes, a common answer to a failed flue
- $2,750 to $5,550
- Water entry located and put right
- $555 to $3,350
- Roof saddle (cricket) upslope of a wide stack
- $445 to $1,005
- Saddle plus a complete change of flashing metal
- $670 to $1,650
- Camera inspection, when the failed report is not one of ours
- $390
- Cap fitted where the report found none
- Quoted after we measure
A liner for an open wood fireplace has no printed range: its figure rests on the flue's inside dimensions and height, both taken at the visit.
Questions after a failed report
Can the fireplace be used until the repair is done?
Not when the report marks the flue as failed. A split or unlined flue lets heat into the chimney wall with every fire, and a gas log set counts as a fire for this purpose.
Does one split tile mean the whole flue gets a liner?
Often it does, because a tile halfway down cannot be swapped without opening the chimney wall. A split in the top tile or two can sometimes be dealt with by replacing those tiles from the roof. The quote says which applies and why.
The failed report came from another company. Can you quote from it?
It tells us what to expect. To price a liner we need the flue's inside dimensions, its height and its bends, so we take those ourselves. If the other report holds no usable camera record, our $390 Level 2 inspection supplies one.
Will the outside of a 1920s chimney look different afterwards?
A liner changes nothing you can see except the cap. Masonry repairs at the top are matched to the old brick and mortar as closely as salvage brick and color tests allow.
Must everything on the report be fixed in one go?
No. The quote groups its lines into those that stop the fireplace being used and those about weather or appearance. The first group has to be complete before a fire is lit. The second can follow in a later season.
Turn the failed report into a priced repair
On the contact form, list the findings from your report and say what the fireplace burns. We phone back to arrange the measuring visit.
Call (657) 233-4679